Why your heat pump runs on emergency heat in Illinois

RepairHeat PumpIllinois
Step 1 of 2

What ZIP code is the job in?

Why did my heat pump switch to emergency heat?

Your thermostat shows "emergency heat" and the heat pump outside has stopped running. With Illinois winters getting cold enough to tax a heat pump's limits, it's worth knowing whether this switch means something is actually wrong or if the system is doing what it's supposed to do when the air gets too cold to pull heat from.

It means the outdoor unit has stopped and your backup heat is doing all the work

Emergency heat is a manual setting that shuts off the outdoor unit completely and hands all the heating over to the backup system, usually electric strip heat or, in some Illinois homes, a gas furnace paired with the heat pump. It switches on because someone, or something, decided the heat pump itself can't be trusted right now. If you didn't set it yourself, that points to a problem with the outdoor unit: a frozen coil, a failed compressor, low refrigerant. Left on emergency heat for days, you'll likely see it on your power bill, since backup heat is less efficient than the heat pump working normally. A heat pump that can't run on its own in the cold is worth having looked at before the backup system becomes the only thing keeping your house warm.

A gray outdoor condenser unit on a concrete pad beside a house with horizontal lap siding, connected by conduit and lines to a wall-mounted disconnect box, with a shrub and gravel bed to the left.

Normal operation

The outdoor unit runs quietly, cycling on and off as the thermostat calls for heat. Below freezing, it may run longer stretches to keep up, and frost on the coil that clears on its own during a defrost cycle is normal. This is your heat pump doing its job.

An outdoor air conditioner condenser unit on a concrete pad beside a house with horizontal lap siding, with refrigerant lines and a gray electrical disconnect box on the wall, surrounded by bare dirt.

Stuck on emergency heat

The outdoor unit sits idle no matter how cold it gets outside, and the heat strips inside are carrying the whole load. A coil caked with dirt and debris like this often can't absorb enough heat from the air to run, which is when a thermostat locks into emergency heat and stays there.

You Flipped It, or It Flipped Itself

Emergency heat is working as designed

  • The switch you flipped yourself to emergency heat tells the system to skip the outdoor unit entirely and run on the backup heat strips or furnace alone.
  • This is meant for when the heat pump itself is down, such as a tripped breaker, a frozen outdoor coil that isn't clearing, or an outdoor fan that won't start.
  • If you turned it on because the house felt cold during a hard freeze, check whether the outdoor unit is actually iced over or silent before leaving it on.
  • Emergency heat draws straight from electric strips or your gas furnace, so leaving it on by mistake runs your bill up fast in an Illinois winter.
  • Once whatever stopped the heat pump is fixed, the thermostat should go back to normal and the switch should go back off.

The system switched over on its own

  • If you never touched the switch and the thermostat shows emergency heat anyway, the system has detected a fault and locked the heat pump out automatically.
  • A common trigger is a failed defrost control or a sensor reading that doesn't match reality, so the board decides the outdoor unit can't be trusted to run.
  • Low refrigerant charge, a bad compressor, or a stuck reversing valve can all force the same automatic lockout.
  • This isn't the heat pump straining against a cold snap, it's the control board deciding something is wrong and stepping aside.
  • A contractor licensed in Illinois who services heat pumps year round can usually tell which of these it is from the fault code and a look at the outdoor unit.
  • Left alone, the house stays warm off backup heat, but the underlying problem doesn't fix itself and the higher electric cost keeps adding up.
A smiling man in a gray long-sleeved shirt stands in a kitchen looking to the side, with open shelves of dishes, a white mug on the counter, a potted plant, and a view through a doorway into a living room.
A smiling bearded man in a green sweater sits at a white marble kitchen island with a mug, potted plant and bowl of fruit, in a bright white interior with open shelving and an arched doorway.
A smiling man with dark curly hair and a beard, wearing a dark green knit sweater, stands at a white marble kitchen counter with a dark blue mug, with open shelving, pendant lights and a houseplant behind him.
A smiling man in a green ribbed sweater stands behind a wooden table holding a ceramic mug of coffee in a kitchen with white subway tile, shelves of potted plants, and a bowl of fruit.
A gray outdoor condenser unit on a concrete pad beside a light-colored lap-sided house, with a wall-mounted disconnect box, refrigerant lines, mulch bed and shrubs, and a concrete walkway in the foreground.
The outdoor unit sits clean on its pad, lines running straight to the disconnect, nothing to flag.
An outdoor air conditioner condenser unit with rust spots on its top grille sits on a concrete pad beside a house with light horizontal siding, with conduit lines and an electrical box on the wall and a mulch bed to the right.
Rust on the grille, dirt packed around the base, this is a unit old enough or neglected enough to start failing on cold nights.

What's Happening Inside the System

  • A reversing valve inside the outdoor unit switches between heating and cooling by redirecting refrigerant flow.
  • A defrost sensor and timer tell the system when to melt frost off the outdoor coil so it keeps absorbing heat.
  • A low pressure switch or high head pressure switch can trip and lock the compressor out, forcing the system onto backup heat.
  • The control board checks outdoor temperature against a set point, and below it, backup heat strips or the furnace carry more of the load automatically.
  • A failed defrost sensor or a stuck contactor can make the board decide the heat pump cannot run, even if the compressor is fine.
  • Auxiliary heat and emergency heat use the same strips or furnace, but auxiliary is the board's choice while emergency heat is the switch you set.

A heat pump moves heat instead of making it, and the reversing valve is what lets it do that both ways. In winter, that valve pulls heat out of the cold outdoor air and pushes it inside. When frost builds on the outdoor coil, a defrost sensor tells the board to briefly reverse that process and run hot refrigerant through the coil to melt it off, then switch back to heating. This happens on its own, several times a day in cold weather, and is not a malfunction.

The board is also watching pressure. If refrigerant pressure runs too low or the compressor's head pressure runs too high, a safety switch trips and shuts the compressor down rather than let it run and damage itself. Once that happens, the board has no outdoor unit to call on, so it leans on backup heat strips or your furnace to keep the house warm.

That's different from emergency heat, which is the switch you set yourself on the thermostat. It tells the system to skip the outdoor unit entirely, whether or not anything is wrong with it. Auxiliary heat, by contrast, is the board stepping in automatically because it's cold outside or because a defrost sensor, contactor, or pressure switch has taken the compressor out of the picture. Same backup heat source, different reason it's running.

Power costs 17.67 cents per kilowatt-hour statewide

At 17.67 cents per kilowatt-hour, running the backup heat strips costs more than running the heat pump itself. If yours is stuck on emergency heat for more than a day or two, that switch is worth sorting out before the next bill shows up.

EIA-861 2025 statewide residential average

A light gray outdoor heat pump unit mounted on a concrete pad beside a house with horizontal lap siding, with refrigerant lines and conduit running to a wall-mounted electrical box, gravel and a leafy shrub nearby.

The unit running clean

A heat pump kept clear of grime pulls heat from the outside air without strain, even on a cold Illinois night. The lines to the disconnect run straight and the cabinet stays free of buildup, which is what lets the system cycle on its own instead of leaning on backup heat strips.

An outdoor air conditioner condenser unit on a concrete pad beside a house with horizontal siding, with conduit, cables and an electrical box on the wall and mulch beds at either side.

The unit caked in dirt

Dust packed into the fins blocks the airflow the coil needs to pull heat from outside. A heat pump working through grime like this falls behind on cold days and can trip into emergency heat, leaving the backup strips to carry the load until the outdoor unit gets looked at.

A smiling man with dark curly hair in a navy t-shirt sits on a gray couch indoors, with a large-leafed plant and a window in the background.
A bearded man in a plaid flannel shirt stands in a kitchen looking out a window toward snow-covered shrubs, with a steaming mug on the windowsill and potted plants on a shelf behind him.
  1. Thermostat calls for heat and signals the outdoor unit first.

  2. A low pressure or high pressure switch trips and locks out the compressor.

  3. The control board cuts power to the outdoor unit to protect it.

  4. The board switches the system over to the backup heat strips or furnace.

A weathered gray outdoor condenser unit sits on a concrete pad beside a house with horizontal siding, with refrigerant lines entering the wall at left and a mulched shrub bed at right.
Before you get your heat pump repair
A gray outdoor condenser unit on a concrete pad beside a house with horizontal lap siding, with an electrical disconnect box and insulated refrigerant lines on the wall, gravel in the foreground and a planting bed at left.
After you get your heat pump repair

Done looking for a heat pump pro

A heat pump that won't come off emergency heat on its own has something stopping it, and most of the time that's a failed sensor, a stuck contactor, or a lockout the control board won't clear until someone resets it right. Running on the heat strips alone isn't dangerous, but at 17.67 cents a kilowatt-hour it's the most expensive way to heat your house in Illinois, and every day it sits like this is a day added to a bill that gas heat wouldn't give you. Gas furnace backup or not, the outdoor unit should be doing most of the work once it's above freezing outside. A contractor who works on heat pumps in this area through every one of these cold snaps has seen this exact failure before and knows where to look first. Getting someone out to check it is one less thing on your plate, and the switch gets flipped back the way it's supposed to run.

An outdoor condenser unit beside a horizontally sided house, encased in thick ice with hanging icicles, on a snow-dusted ground at sunset with bare trees in the background.

You go out for the paper a little after six, and the sky is just starting to gray. The side yard is quiet, your breath showing in the air. The outdoor unit sits against the house wearing a thick shell of ice, over the coil and down the sides of the cabinet, nothing like the thin frost that melts off on its own most mornings. No hum, no fan turning. Inside, the thermostat reads emergency heat. You stand there a second with the cold coming through your slippers, looking at the ice, before you head back in to call someone.

What are you noticing right now with your heat pump

The thermostat display says emergency heat and you didn't put it there. The outdoor unit is silent, no fan, no hum, nothing moving even though it's cold enough outside that it should be running. Inside, the air coming out of the vents feels hotter than usual, almost like a furnace rather than the steadier warmth a heat pump puts out. Your electric bill is the place this shows up next, since the backup strips draw a lot more power than the compressor outside ever did. If this goes on for days without anyone looking at it, you're paying for heat the hard way and the actual problem, whatever tripped the system into backup mode, is still sitting there unresolved.

A single-story gray horizontal-siding house with multiple front-facing gables, white-trimmed windows, a dark front door, and a concrete walkway crossing a partly dry lawn under a clear blue sky.

Illinois summers aren't just hot, they're sticky, and that works the heat pump's outdoor coil in a different way than dry heat does. Averaged across June, July and August, the dew point here runs 63°F, which means the coil is pulling moisture out of the air along with heat every time it cycles. That extra load doesn't cause the emergency heat switch you're dealing with now, but it does mean the same unit has been working harder all summer. A coil that's been running damp and dirty into fall is more likely to have a sensor or switch already on the edge of tripping once the cold sets in.

NASA POWER T2MDEW county cells weighted by homes

A heat pump stuck on emergency heat almost always comes down to one thing stopping it from switching back: a sensor that failed, a switch that tripped, or a lockout sitting in the control board. That's a repair, not something to wait out through a stretch of cold nights while the heat strips run up the bill. Someone who services heat pumps in Illinois year round has seen this exact fault more times than not, knows which part tends to go first on units like yours, and can usually tell within a few minutes whether it's a defrost sensor, a stuck contactor, or something else. You'll be matched with one licensed contractor local to you, not a handful of companies competing for the job, so there's one call to field and one person who already knows what to check before they get to your door. Once that request is in, finding the right contractor isn't on you anymore. The heat pump will likely need a look either way. Getting it fixed means the outdoor unit goes back to doing the work, and the heat strips go back to backup, which is what they were built for in the first place.

Close view of a dark standing-seam metal roof with a stone chimney and metal flue cap, overlooking a wide river, trees, and flat farmland under a partly cloudy sky.

It's off your list after this

Send it today

It costs nothing to send, and you don't have to hire anyone.

A heat pump running on strip heat through a long stretch of Illinois cold adds up fast on the power bill. Getting it looked at sooner means fewer days paying that higher rate, and a working heat pump again before the next cold snap settles in for good.