Electricity here isn't cheap
Illinois homes paid 15.87 cents per kilowatt-hour in 2024. A dirty coil or a low charge makes the compressor run longer to do the same job, and that shows up on the bill every month the system runs.
Takes about a minute. No obligation.
Illinois homes paid 15.87 cents per kilowatt-hour in 2024. A dirty coil or a low charge makes the compressor run longer to do the same job, and that shows up on the bill every month the system runs.
A technician cleaning the coil, checking refrigerant charge and testing the capacitor catches the kind of wear that makes a unit work harder than it should. Catching it before summer means the system isn't fighting itself all season.

NOAA nClimDiv, 1991–2020 normals
A quick tune-up checks that the unit turns on and blows cold.
A thorough one opens the cabinet, checks the capacitor under load, and measures refrigerant charge against the manufacturer's numbers.



Cooling runs June through August here, three months total, and June is when it starts working hardest. May is the month to have someone look at it, before that first stretch of heat. A system checked in May gets any repair done while there's no rush. Wait until the unit is already running flat out in June and a bad part means a hot house until someone can get to it.
A neglected system uses more power, and power costs more here. A tune-up pays for itself.
Find a contractorA compressor that runs every day for months doesn't get a break to show you small problems before they become big ones. A capacitor that's starting to weaken still starts the unit most days. It just takes a little longer each time, and that extra strain wears on the compressor itself. A coil that's picking up dust still moves air, just not as much, so the system runs longer to reach the same temperature. None of this trips a breaker or makes a noise you'd notice. The unit keeps running, worse each week, until a part that was limping finally quits, usually on the hottest day it's worked all year. A check during a quiet stretch catches the capacitor testing weak or the charge sitting low before either one takes something else down with it.
The refrigerant charge, the capacitor's actual output under load, the condition of the contactor points. None of this shows from outside, and none of it changes how the unit sounds when it kicks on. A technician with gauges and a meter checks these against the numbers the manufacturer specifies, not against a guess of what seems fine.
A system low on charge still blows cold air at the vent, just not cold enough. Most people can't tell the difference by hand. Checking the charge against the right pressure for that unit catches a slow leak or an undercharge months before the compressor starts struggling to keep up.
A tune-up checks the refrigerant charge, cleans the coils, tests the capacitor and tightens the electrical connections.
A tune-up means someone actually opens the unit up, not just runs it for a minute and calls it good. Outside, the condenser coil gets washed down, since a coil caked with grass clippings and cottonwood can't shed heat the way a clean one does, and that makes the compressor run longer for the same result. The fan motor and blades get checked for wobble or noise, because a bearing going bad in the motor will eventually seize it. The contactor points get looked at too, since those pit and burn with every cycle and a worn set can stick or fail to close. Inside, the evaporator coil and the drain line get checked, since a clogged drain backs up and overflows into the house instead of outside where it belongs. The whole system gets run through a full cycle afterward, not just switched on, to see that it actually holds the temperature it's set to.