Three months of real work
Your AC only has to carry the load from June through August here, with afternoon highs averaging 81°F. That's a short stretch compared to what the same unit would face further south.
Takes about a minute. No obligation.
Your AC only has to carry the load from June through August here, with afternoon highs averaging 81°F. That's a short stretch compared to what the same unit would face further south.
A compressor that isn't run hard all year has less wear behind it. If your AC is acting up, the problem is more likely one part giving out than the whole system being worn through.

NOAA nClimDiv, 1991–2020 normals
A capacitor failing is the most common reason a compressor or fan motor won't start.
That's a part swap, not a system failure, and it's worth having a tech confirm before anyone talks about replacing the unit.



May is worth paying attention to if your AC has been off all winter. Homes here start running cooling in June, and that first real stretch of heat is when a weak part tends to show itself. A capacitor that was marginal last August doesn't get better sitting idle all winter. If your system struggled at the end of last summer, get it looked at before June rather than after it's already working hard. Catching it before the season starts usually means a part swap instead of a breakdown on the first hot day.
A part giving out is a repair call, not a reason to replace the system. Get it looked at and find out which part this is.
Find a contractor
If your AC came with the house, check for a build date before you assume the worst. A system installed when the house was built, or replaced once since, is probably not old enough to be failing on its own. That matters when you're deciding what to do about a repair quote. A capacitor or a fan motor is worth replacing on a unit that still has years ahead of it. Whole-system wear is a different conversation, and it's not the one most homes here are having yet.
Look at the outdoor unit first. If the fan isn't spinning and you don't hear a hum, check the breaker before anything else. A tripped breaker or a switch bumped off at the disconnect box near the unit will stop the whole system cold. Inside, check the thermostat is set to cool and the setpoint is actually below room temperature. Then check the filter. A filter clogged with dust chokes airflow across the coil, and that alone can make a system blow warm air or ice up.
Don't pull the access panel on the outdoor unit or touch anything inside it. The capacitor in there holds a charge even with the power off and can give a real shock. If the line connecting the two units has ice on it, turn the system off and let it thaw rather than chipping at it. Running a frozen system only pushes liquid refrigerant back toward the compressor, and that's a part that's expensive to replace if it gets damaged.
Estimates for a typical Boone County home, compared with an older unit built to the previous federal minimum, from EIA household energy data, Illinois fuel prices and NOAA climate normals. Your home will differ.
Repair makes sense when a part like a capacitor or contactor has failed.
Replacement makes sense when the compressor has failed or the system uses R-22 refrigerant, which is no longer made.
A diagnostic call starts outside at the unit itself, watching whether the fan spins and listening for the compressor coming on. From there it's a gauge set on the refrigerant lines to check the charge, because low refrigerant points to a leak somewhere in the system rather than a part just wearing out. The capacitor gets tested under load, since one can look fine sitting still and still fail to kick the compressor on. Electrical connections get checked too, loose wiring and burnt contacts cause their own share of no-start calls. All of it is pointing at one thing: finding which single part failed, rather than assuming the whole unit is done.